Fluid Sensing Cable with 4 important points
This is Frank from Prosino Group,you could lean our water leak detection system or water leakage detection cable/controller sensor
Today I would like to share the information about water leakage
Most of water leakage was happening indoor or outdoor
The indoor applications as below:
- Airports,Banks,Churches,Clean Rooms,Correctional Facilities,Hospital,Hotels
- Medical Facilities,Nursing Homes,Office Building,Residential Facilities,
- Retail,Schools,Telecommunications, Theaters,University,Warehouse and so on
- the outdoor applications:most of water leakage happening is piping system
- I am good at indoor water leakage detecting, It is our company Prosino Group’s mission to make the world a safer place
- Not only in EU and US,But also in all of the world Fluid sensing cable or water leakage detection cable
- was widely used in environment monitoring system,it is specially in server room,data center,water tank and more
Now I am here to introduce the product of fluid sensing cable.
There are 2 versions of water leak detection cable .
1)P-LFP1000-Addressable (position) water leak detection cable.
- Each meter with 13 ohm resistance
- The diameter is 6.0 mm
- 4 wires fluid sensing cable
- The color could be customized expect the 2 black sensing wire
- The length could be customized according to request
- We suggest 10 meters,15 meters,20 meters,the functions per each wire as below photo
2)P-LFP1B-Non position fluid sensing cable
- The diameter is 6.0mm or 4.5mm
- 2 wires water leakage detecting cable
- The color could be customized expect the 2 black sensing cable
- The length could be customized according to the request
Below are the liquid leakage detectors
There are also 2 versions of liquid leakage detector (alarm)
1)P-LFP1-Position controller
- Able to detect the distance as long as 1,000 meters and the tolerance is 0.5%,it is with RS485 and switch output
- It is addressable water leakage detector
- It is with RS485 and switch output
- RS485 output which is communicating with computer or monitoring host,it is always with 2 RS485 connectors,1 pair for input,another pair for output(if you would like to combine with more RS485 devices)
- Switch output,which is communicating with other equipment
- Tolerance is 0.5%
- Power supply : Between : 5V -24V
- There are 3 LED lights
- Power —– It is power light
- Service —— It means breaking. Or the cable did not connected well
- Leak ——- When the leakage is happening . The light will flash
- RS485 . B- A+ B- A+ . It is 2 pairs of RS485 connectors
- Alarm Replay . It is switch output only available with the device,which power is between 5V- 24V,It is with N.O,N.C,COM
- It is always only connect 2 cable,The method as below:
- and COM,or N.C and COM,Power of both of N.O,and N.C device is between 5V-24V
- When the cable detected the leakage is happening,after you push the “confirm “button . The “ leak” led light will turn off
- And the leakage position will bed disappeared
- So please record the leakage position and inform the staff to handle the leakage before you push “ confirm” button
- When you push the second time “ confirm “ button . It is normal working
- I would like to enclosed the full addressable water leak detection system photo:
2)P-FP1A-Non position alarm
- Non-position water leak detector
- The sensitive button-There are 3 models of sensitive,Low,Middle,High
- This model is single way non position water leak detector
- VCC and GND-It is for power . VCC means V+ , GND means V-
- RS+ , RS- -Please make sure it is correct connection
- Here I am also would like to enclosed the full non position water leak detection system:
Conclusion .
Position water leak detection system
- Power supply (5V-24V) + Position detecting alarm +Lead cable + addressable fluid sensing cable +clearing end
Non position water leakage detect system
- Power supply (5V-24V) +non position detecting alarm +Lead cable + fluid sensing cable + terminal
- If you would like to contact me,Please email to: frank@prosinogroup.com